Functional requirements. It can meet the requirements of intraoperative fluoroscopic positioning of spine, trauma, joints, limbs, pain departments, etc.
//www.txmedtech.com/uploadfiles/128.1.164.122/webid2093/source/202209/166398797684.jpg
Product Detail

Specification:

1 Functional requirements

1.1 It can meet the requirements of intraoperative fluoroscopic positioning of spine, trauma, joints, limbs, pain departments, etc.

2 Configuration Requirements

2.1 Combined integrated tube (Northwest Machine) 1 set

2.2 Image intensifier (Thales) 1 set

2.3 C-arm host (northwest machine) 1 set

2.4 Instrument car (Northwest Machine) 1 set

2.5 Monitors (Dell) 2

2.6 Wire grid (King) 1 piece

2.7 CCD camera (Northwest Machine) 1

2.8 Image Workstation (Northwest Machine) 1 set

2.9 Beamer (Northwest Machine) 1

Technical parameters of mobile C-arm X-ray machine

3 C-arm main frame

3.1 Horizontal movement 200mm

3.2 Vertical lift 400mm

3.3 C-arm track displacement 125° (-35°—+90°)

3.4 C-arm rotation flip ±200°

3.5 Left and right swing angle ±12.5°

3.6 C-arm arm depth 630mm

3.7 SID 1000mm

3.8 Both the main engine and the instrument car are equipped with brake function, which is convenient for operation. The host can move horizontally in place and move flexibly. have

4 Combined integrated tube

4.1 Maximum output power 5.3kW

4.2 Inverter frequency 40kHz

4.3 Maximum voltage 110KV

4.4 Maximum perspective current 10mA

4.5 Photography mode kV range: 40 ~ 110kV

mA range: 50 ~ 75mA

mAs range: 0.4 to 500 mAs

4.6 Perspective mode kV range: 40 ~ 110kV

mA range: 0.2 ~ 5.0 mA (general perspective)

mA range: 10mA (enhanced perspective)

5 X-ray tubes

5.1 Tube focus Small focus 0.3mm; Large focus 0.6mm

6 Image intensifier Three fields of view 9″, 6″, 4.5″

6.1 Line pair resolution 2.2LP/mm

6.2 CCD camera megapixels

6.3 Grayscale Level 9

7 Grid (Korean King)

7.1 Beam limiter with

7.2 Grid 100line/cm

8 monitors

8.1 Monitor 2 17-inch high-resolution monitors

8.2 Maximum resolution ≥1920×1080

8.3 Working frequency 60HZ

9 Digital image processing functions

9.1 The image is flipped horizontally and vertically Yes

9.2 Image 360° Rotation Yes

9.3 Image inversion Yes

9.4 Real-time image window width and window level processing Yes

9.5 Image real-time gain processing Yes

9.6 Image real-time edge enhancement processing Yes

9.7 Image real-time dynamic noise reduction processing Yes

9.8 RIS/HIS/PACS seamless connection, printable graphic pathology report