High-definition 10.4 TFT color LCD display

Ventilation mode :
VCV、PCV、SIMV、PSV、PSV+SIMV、CPAP

Ventilation function:
PEEP、SIGH、Standby, inhalation platform, inverse proportional ventilation
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
img of mask_layer_close
Mechanical Ventilator TX-MDW-AK2000B2
Product Detail

Specification

Display method:

High-definition 10.4 TFT color LCD display

Ventilation mode :

VCV、PCV、SIMV、PSV、PSV+SIMV、CPAP

Ventilation function:

PEEP、SIGH、Standby, inhalation platform, inverse proportional ventilation

Ventilation parameters

Tidal volume:20~1800 ml

Frequency:2~120 times/min

SIMV frequency:2~20 times/min

Breathing ratio:4:1~1:8

Pressure trigger pressure:-10~10cmH2O

Flow trigger sensitivity:1~20 L/min

PEEP:0~25cmH2O

Pressure control:3~50cmH2O

Pressure limit:5~60cmH2O

Pressure slope:1~10

Traffic settings:1~10

Respiratory Sensitivity:10>%~90%

Time control:1~10s

Sigh: 1.5 times the inspiratory time (adjustable from 60 to 120 times)

Air suction platform:0~50%

Oxygen concentration: 21%~99%

■ Ventilation monitoring

Expired tidal volume, inspiratory tidal volume, ventilation volume, IPPV frequency, SIMV frequency, total respiratory rate, spontaneous inspiratory rate, inspiratory ratio, peak airway pressure, mean pressure, positive end expiratory pressure, inspiratory trigger pressure, inspiratory Air platform, oxygen concentration, battery capacity, pressure-time waveform, flow rate-time waveform, flow rate-volume loop, pressure-volume loop

■ Security alarm system

Oxygen concentration alarm

Upper limit setting range 21%~99%

Lower limit setting range:18%~80%

Airway pressure alarm

Upper limit setting range 5~60cmH2O

Lower limit setting range:0~50cmH2O

Minute ventilation alarm

Upper limit setting range 1~20L/min

Lower limit setting range:0~19L/min

Tidal volume alarm

Upper limit setting range:10~1800ml

Lower limit setting range:0~1700ml

Frequency alarm

Upper limit setting range:10 to 99 times/min

Lower limit setting range:0~50 times/min

Continuous high pressure alarm

Alarm when the pressure is continuously higher than 30cmH2O

Choking alarm

Power outage alarm

Low air supply alarm

Pipe fall off alarm

Low oxygen supply alarm

Battery undervoltage alarm

■ Power supply:

AC 220V,50Hz,UPS power supply, battery